Vitaclaris
The method

How Vitaclaris Age works

One model, every measure adding up, and a range that says how sure it is. Here is everything behind the number: the survey, your measures, how well it works and what it can't tell you.

What it is, and what it isn't

Vitaclaris Age compares your measures with people your age and sex in a large US health survey, and says how many years older or younger your measures look, from how people with measures like yours fared on average. A 52-year-old woman whose measures look like those of a typical 49-year-old woman has a Vitaclaris Age of about 49.

It is not a diagnosis, and it is not a prediction for you. It says how people with measures like yours fared on average, years ago, in a survey of the US population; it can't tell what will happen to one person. It shows links, not causes: a measure that "adds years" isn't proven to cause anything. Talk with your doctor before changing a treatment.

The data

  • The survey: the US National Health and Nutrition Examination Survey (NHANES), ten two-year cycles from 1999–2000 to 2017–2018, run by the CDC's National Center for Health Statistics. Each person had an interview, an exam and blood tests.
  • What happened next: the NCHS 2019 public-use linked mortality files, which link survey participants to the National Death Index through December 31, 2019.
  • Who's in it: 47,122 people aged 20 to 79 at their exam (the survey records everyone 80 and over as 80, so they are left out), not pregnant, and eligible for the mortality link. Over a median of 9.3 years, 5,756 of them died.
  • Only public files, only summaries: the model was fitted on the CDC's public-use files. The app holds only the model's coefficients, never anyone's record.

Your measures

Vitaclaris Age rests on up to 15 measures. Each one counts the way the survey measured it.

MeasureFrom the surveySurvey cycles
Blood pressure (systolic)Mean of the exam's 2nd to 4th readings1999–2018
Resting heart rate60-second seated pulse at the exam1999–2018
Waist-to-height ratioMeasured at the exam1999–2018
HbA1cBlood test1999–2018
HDL cholesterolBlood test1999–2018
TriglyceridesFasting blood test (the morning half of the sample)1999–2018
Kidney function (eGFR)Creatinine, CKD-EPI 2021 equation without race1999–2018
CRPBlood test1999–2010, 2015–2018
SmokingNever, former, current1999–2018
AlcoholMore than 14 drinks a week, or not1999–2018
ExerciseModerate-equivalent minutes a week (a vigorous minute counts twice)2007–2018
SleepUsual hours a night, as people reported them2005–2018
Grip strengthBest reading of either hand2011–2014
Cardio fitness (VO2 max)Borrowed from a published study (below)—
Daily stepsBorrowed from a published study (below)—

A measure you haven't added counts as average for your age and sex: it neither adds nor takes off years, and it widens your range.

Measures from some cycles only: where the survey didn't take a measure (sleep before 2005, grip strength outside 2011–2014, CRP in 2011–2014, triglycerides outside the fasting half, exercise minutes before 2007), the model fills it in from each person's other measures (multiple imputation, five times over, combined by Rubin's rules). The app says which cycles each measure comes from.

Borrowed effects: the survey tested cardio fitness only up to age 49, and its 2011–2014 accelerometers report activity units, not steps. These two come from published studies instead:

  • Cardio fitness: each MET (3.5 mL/kg/min) of fitness went with 14% lower mortality, HR 0.86 (95% CI 0.85–0.87), in 750,302 US veterans (Kokkinos et al., J Am Coll Cardiol 2022). Your value is compared with the median for your age and sex in the FRIEND registry (Kaminsky et al., Mayo Clin Proc 2015).
  • Daily steps: each 1,000 steps a day went with 15% lower mortality, HR 0.85 (95% CI 0.81–0.91), across 17 cohorts and 226,889 people (Banach et al., Eur J Prev Cardiol 2023), counted between 2,000 and 12,000 a day, where the studies' curve is steepest. Your steps are compared with one figure, not by age and sex: the US adult average of 6,540 steps a day from the survey's 2005–2006 hip-worn step counters (Tudor-Locke et al., Med Sci Sports Exerc 2009). Older people take fewer steps on average, so this reads a little hard on them.

They partly overlap with exercise minutes, so they can count some of the same activity twice; their studies' uncertainty is added to your range.

Each measure's years add up to the total. Every measure is in the same model, so its effect is adjusted for the others: measures that move together (waist, HbA1c and triglycerides; exercise, grip and steps) share their years instead of counting twice. Each is compared with people of your own sex and age, so being a woman or a man never moves your number by itself.

No clear effect: in this model, waist-to-height ratio, HDL cholesterol and triglycerides have 95% intervals that cross zero once the other measures are counted. The app says "no clear effect in this model" for them and shows their years only as a range.

From your devices

  • Sleep: people report about 0.8 hours more sleep than a wrist device measures (Lauderdale et al., Epidemiology 2008). A device's time asleep gets 0.8 hours added to match how the survey asked, and 0.8 hours of uncertainty is added to your range.
  • Resting heart rate: a device's value (often measured overnight) is used as the survey's seated pulse, with ±5 beats per minute added to your range. We found no published conversion to apply, so this is an assumption.
  • A night's lowest heart rate (worked out from overnight heart rate when a device doesn't write a resting heart rate) isn't counted. It's taken asleep, and a sleeping heart rate runs lower than a seated pulse by an amount that differs from person to person, with no published conversion. Heart shows it for information; here a recent resting heart rate or a seated pulse you enter counts instead.
  • Cardio fitness from a watch: in the one published accuracy study of Apple Watch's estimate (30 people against a treadmill test), the average error was 6.92 mL/kg/min and the watch read about 6 low on average (Lambe et al., PLOS ONE 2025). We add ±6.9 to your range; we don't correct the low reading, since it comes from one small study. A lab test replaces the watch's estimate. A VO2 max you enter counts as a lab test only when you say it came from one; otherwise, including one entered before Vitaclaris asked, it counts as an estimate, with the ±6.9.
  • Vaping only: the survey didn't ask about it, so it counts as average.
  • Beta blockers slow the heart, so resting heart rate doesn't count while you take one.

How well it works

The model was checked on a fifth of the people (9,424) who were held out and never used to fit the version being checked:

  • Telling people apart (C-index): 0.827. Age and sex alone give 0.798, so your measures add 0.029. A C-index of 0.5 is a coin toss; 1 would be perfect.
  • Calibration: predicted against observed deaths over 10 years, in each tenth of predicted risk:
Tenth of riskPeoplePredictedObserved
1 (lowest)9430.3%0.7%
29420.6%1.5%
39421.1%1.4%
49431.8%2.1%
59423.1%4.1%
69425.2%5.0%
79438.5%8.1%
894214.2%15.6%
994223.1%24.1%
10 (highest)94346.0%43.4%

Said plainly: the model underestimates risk for the lowest-risk people. In the lowest two tenths it predicted 0.3% and 0.6% and the observed figures were 0.7% and 1.5%. The gap is small in absolute terms, under one percentage point of 10-year risk, but it is real: for the healthiest people Vitaclaris Age reads a little younger than their observed risk would. In the highest tenth it slightly overestimates (46.0% predicted, 43.4% observed).

What the range means

Your number comes with a 90% range. It adds up four kinds of uncertainty: the model's own (from fitting it), each measure you haven't added (how much people your age and sex vary on it), each device estimate's error, and the borrowed studies' uncertainty. The more measures you add, and the more of them from a lab or a measured test, the narrower it gets. It doesn't include the uncertainty of the survey itself standing in for you.

A week-to-week move inside the range's usual wobble reads "no real change".

What it can't tell you

  • It compares you with Americans examined from 1999 to 2018; people elsewhere, or today, may differ.
  • It knows only what you've added; a condition, a medicine or a family history it doesn't hold isn't counted.
  • It describes groups, not you: two people with the same Vitaclaris Age can have very different futures.
Technical appendixThe model, its terms and how the range is worked out, for readers who want the equations.

Model. Cox proportional hazards on months from the exam to death from any cause (or censoring at December 31, 2019), with age at the exam, sex and the measures' terms as covariates; the survey's exam weights pooled over ten cycles (4-year weights × 2/10 for 1999–2002, 2-year weights × 1/10 after) as case weights; robust (sandwich) standard errors. Missing values by chained-equation imputation (each continuous measure regressed on age, age², sex, smoking and the others, with residual noise; smoking drawn within sex and age band), five data sets, pooled by Rubin's rules.

Vitaclaris Age. age + Σₖ βₖ · (xₖ − mₖ(age, sex)) / β_age, where mₖ is the survey-weighted mean of term k for that age and sex (a quadratic in age, by sex), so each measure's years sum to the total and a missing measure counts 0. β_age = 0.0774 per year.

Terms (log hazard ratio, 95% CI, years per unit = β / β_age):

TermTransformlog HR95% CIYears per unitClear effect
SystolicmmHg, 90–2000.00530.0037 to 0.0069+0.07yes
Pulsebpm, 40–1200.01130.0088 to 0.0138+0.15yes
Waist-to-heightratio, 0.35–0.850.4048−0.0497 to 0.8592+5.23no
HbA1c% above 5.40.14210.1135 to 0.1706+1.84yes
HDLln mg/dL−0.0304−0.1738 to 0.1129−0.39no
Triglyceridesln mg/dL−0.0106−0.0934 to 0.0723−0.14no
eGFRmL/min/1.73m² below 900.01310.0109 to 0.0153+0.17yes
CRPln mg/L, 0.15–200.12300.0901 to 0.1559+1.59yes
Former smokeryes/no0.29300.2194 to 0.3666+3.79yes
Current smokeryes/no0.94260.8622 to 1.0229+12.18yes
Alcohol over 14 a weekyes/no0.24520.1202 to 0.3701+3.17yes
Exerciseln(1 + min/week)−0.0415−0.0647 to −0.0182−0.54yes
Sleep under 7 hhours below 70.08290.0442 to 0.1216+1.07yes
Sleep over 8 hhours above 80.13110.0696 to 0.1925+1.69yes
Grip strengthper 10 kg−0.1001−0.1643 to −0.0359−1.29yes

The range. ±1.645 standard deviations of: the delta method on the pooled covariance of the coefficients; for each missing measure, βₖ² · sdₖ(age, sex)² / β_age²; for each device estimate, (slope × error / β_age)²; for each borrowed effect, (difference × its standard error / β_age)².

Sources

  • National Center for Health Statistics. National Health and Nutrition Examination Survey, 1999–2018, public-use data files. Centers for Disease Control and Prevention. https://wwwn.cdc.gov/nchs/nhanes/
  • National Center for Health Statistics. 2019 Public-Use Linked Mortality Files. https://www.cdc.gov/nchs/data-linkage/mortality-public.htm
  • Kokkinos P, et al. Cardiorespiratory fitness and mortality risk across the spectra of age, race, and sex. J Am Coll Cardiol 2022;80:598–609. doi:10.1016/j.jacc.2022.05.031
  • Banach M, et al. The association between daily step count and all-cause and cardiovascular mortality: a meta-analysis. Eur J Prev Cardiol 2023;30:1975–1985. doi:10.1093/eurjpc/zwad229
  • Kaminsky LA, et al. Reference standards for cardiorespiratory fitness measured with cardiopulmonary exercise testing: data from the Fitness Registry and the Importance of Exercise National Database. Mayo Clin Proc 2015;90:1515–1523.
  • Tudor-Locke C, Johnson WD, Katzmarzyk PT. Accelerometer-determined steps per day in US adults. Med Sci Sports Exerc 2009;41:1384–1391.
  • Lambe et al. Investigating the accuracy of Apple Watch VO2 max measurements: a validation study. PLOS ONE 2025;20:e0323741.
  • Lauderdale DS, et al. Self-reported and measured sleep duration: how similar are they? Epidemiology 2008;19:838–845.
  • Inker LA, et al. New creatinine- and cystatin C–based equations to estimate GFR without race. N Engl J Med 2021;385:1737–1749.
  • Rubin DB. Multiple Imputation for Nonresponse in Surveys. Wiley, 1987.
  • Harrell FE, et al. Evaluating the yield of medical tests. JAMA 1982;247:2543–2546.

See Longevity

Get Vitaclaris

Download it, hear about what's new, or tell us what you'd like next.

Download

Vitaclaris: Health & Longevity, on the App Store for iPhone and iPad, with a free week to start.

Download on the App Store
QR code for vitaclaris.com/get
On a computer? Scan this with your iPhone's camera, or go to vitaclaris.com/get.

Get updates

News about Vitaclaris, such as new versions and features.

We use your email only for Vitaclaris's news, never share or sell it, and take you off the list whenever you ask. Privacy Policy

Suggest a feature

What should Vitaclaris do next?

Write a suggestion

Please don't include personal health information. We may use the ideas you send to improve Vitaclaris, without owing you anything for them. Privacy Policy

VitaclarisUpdatesGet the app